Line 12: Line 12:
10 Max height wrt SHAPE (scale units, in shape units. So a higher Q will result in a smaller scale unit. Scale unit is something like "diameter of body"/Q) 10 Max height wrt SHAPE (scale units, in shape units. So a higher Q will result in a smaller scale unit. Scale unit in physical distance is something like "diameter of body"/Q)

This sets the parameters that limber uses.

Ryugu

'SHAPEFILES/SHAPE.TXT' Initial (Nolan q=64) ICQ model (need to update this each time, or make sure SHAPE.TXT is the current model)
1         appears in LIMVECS.TXT if d > 90 pixels 
1         PICNM.LIM created if d > 90 pixels
20        Max search range in image pixels
2         Search expansion factor (higher values search further away, Bob says to use a value of 3 with impunity)
10        Max height wrt SHAPE (scale units, in shape units. So a higher Q will result in a smaller scale unit. Scale unit in physical distance is something like "diameter of body"/Q)
12        Max phase for terminators (degrees)

Calypso

  • max search range in pixels down to 10 (from 100) because Calypso is so tiny.
  • max phase for terminators to 10, then 20, then 30 because he wasn’t liking the results.
  • max height wrt shape down to 10, then up to 15
  • scaling factor up to 4, then down to 3.

Lutetia

  • LMX=20
  • Zhgt=25
  • Vres=15
  • Zres=15

67CG

  • LMX=99
  • Zhgt=50
  • Vres=10
  • Zres=15
  • ZEXP=2